Search results for "Sample dilution"

showing 2 items of 2 documents

Improving efficiency of viability-qPCR for selective detection of infectious HAV in food and water samples.

2017

Aim: To improve the efficacy of intercalating dyes to distinguishing between infectious and inactivated hepatitis A virus (HAV) in food. Methods and Results: Different intercalating dyes were evaluated for the discrimination between infectious and thermally inactivated HAV suspensions combining with the RT‐qPCR proposed in the ISO 15216. Among them, PMAxx was the best dye in removing the RT‐qPCR signal from inactivated HAV. Applied to lettuce and spinach, PMAxx–Triton pretreatment resulted in complete removal of the RT‐qPCR signal from inactivated HAV. Likewise, this study demonstrates that this pretreatment is suitable for the discrimination of inactivated HAV in shellfish without further …

0301 basic medicineviruses030106 microbiologyBiologyWastewaterReal-Time Polymerase Chain ReactionApplied Microbiology and BiotechnologyMicrobiology03 medical and health sciencesSpinacia oleraceaVegetablesAnimalsSample dilutionInfectious virusShellfishShellfishInfectivityViability PCRSewageInoculationfungivirus diseasesWaterGeneral MedicineLettuceOstreidaeHepatitis a virusdigestive system diseasesBivalvia030104 developmental biologyFoodFood MicrobiologyRNA ViralHepatitis A virusBiotechnologyJournal of applied microbiology
researchProduct

Performance and Specificity of 6 Immunoassays for TSH Receptor Antibodies: A Multicenter Study

2017

Background: The measurement of TSH receptor (TSHR) antibodies is warranted for diagnosis of Graves’ disease (GD). Objective: The performance, detection sensitivity, and specificity of 6 TSHR immunoassays were compared. Methods: Two bioassays and 4 binding assays (Kronus, Immulite, Kryptor, Dynex) were compared in a dilution study performed in patients with autoimmune thyroid disease. Both bioassays were compared to 2 binding assays using stimulatory (M22) and blocking (K1–70) monoclonal antibody (MAb) mixtures. Results: Thirty samples from stimulatory (TSAb)-positive/blocking (TBAb)-negative patients with GD were diluted serially and measured in all assays. Samples were positive until dilut…

medicine.medical_specialtyendocrine system diseasesmedicine.drug_classEndocrinology Diabetes and Metabolism030209 endocrinology & metabolismMonoclonal antibodyThyroiditis03 medical and health sciences0302 clinical medicineInternal medicinemedicineBioassaySample dilutionReceptorTranslational Thyroidology / Original Paperbiologybusiness.industrymedicine.diseaseMolecular biologyAnti-thyroid autoantibodiesEndocrinologyMulticenter study030220 oncology & carcinogenesisbiology.proteinAntibodybusinessEuropean Thyroid Journal
researchProduct